Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Chinese Medical Journal ; (24): 2527-2534, 2017.
Article in English | WPRIM | ID: wpr-248950

ABSTRACT

<p><b>BACKGROUND</b>Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique.</p><p><b>METHODS</b>Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws' positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed.</p><p><b>RESULTS</b>Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide wire attempts in the robot-assisted group was significantly less than that in the freehand group (median [Q1, Q3]: 1.0 [1.0,1.0] time vs. median [Q1, Q3]: 7.0 [1.0, 9.0] times; χ2 = 15.771, respectively, P < 0.001). The instrumented SI levels did not differ between both groups (from S1 to S2, χ2 = 4.760, P = 0.093).</p><p><b>CONCLUSIONS</b>Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible.</p>

2.
Chinese Journal of Surgery ; (12): 555-559, 2012.
Article in Chinese | WPRIM | ID: wpr-245829

ABSTRACT

<p><b>OBJECTIVES</b>To investigate a new targeting mechanical arm for CT-based navigated percutaneous fixation of pelvic fractures, and to evaluate the safety and efficiency of the procedures.</p><p><b>METHODS</b>Using CT-based 3D navigation software combined with targeting mechanical arm, percutaneous insertion of pelvic models (3 dry human cadaver pelvic skeletons and 5 plastic Sybone pelvic models) were performed, 8 pelvic models allowed percutaneous cannulated screw insertion of both S-I joint (2 S-I screws placement for each side, total 32 screws in this experiment) and both superior ramus (1 ramus medullary screw placement for each side, total 16 screws in this experiment). Percutaneous insertion of pelvic models (4 dry human cadaver pelvic skeletons and 4 plastic Sybone pelvic models, 1 S-I screws and 1 ramus medullary scre placement for each side, 32 screws in this experiment) were performed using fluoro-navigation system (Stryker, USA). Time necessary for every screw insertion were recorded. Accuracy of screw placement was assessed using C-arm imaging and direct eyes inspecting. The time and accuracy of the two methods were compared.</p><p><b>RESULTS</b>The time required for the CT-based 3D navigation procedure (3.6 ± 1.2) min was significantly less than using the targeting mechanical arm compared to drilling freehand with navigation (9.1 ± 0.8) min (t = 2.50, P < 0.01). There was no significant difference in accuracy between the two methods.</p><p><b>CONCLUSION</b>CT-based 3D navigation software combined with targeting mechanical arm should be potential to apply percutaneous sacroiliac screwing for pelvic fractures with more accurate and more reliable.</p>


Subject(s)
Humans , Bone Screws , Cadaver , Fracture Fixation, Internal , Methods , Models, Anatomic , Pelvic Bones , General Surgery , Software , Surgery, Computer-Assisted , Methods
3.
Chinese Medical Journal ; (24): 3906-3911, 2011.
Article in English | WPRIM | ID: wpr-262601

ABSTRACT

<p><b>BACKGROUND</b>Computer-assisted procedures have recently been introduced for navigated femoral neck screw placement. Currently there is little information available regarding accuracy and efficiency of the different navigated procedures. The aim of this study was to compare two fluoroscopic navigation tracking technologies, a novel bi-planar robot navigation and standardized optoelectronic navigation, versus standard freehand fluoroscopic insertion in a Synbone hip model.</p><p><b>METHODS</b>Eighteen fixed Synbone hip models were divided into 3 groups. C-arm navigated cannulated screws (AO-ASIF, diameter 7.3 mm) were inserted using freehand targeting (control group). A novel bi-planar robot system (TINAV, GD2000) and an optoelectronic system (Stryker OTS Navigation System) were used for the navigated procedures (robot group and optoelectronic group). Accuracy was measured using radiographic evaluation including the measurement of screw parallelism and decentralization, and joint penetration. To evaluate the efficiency, the number of guidewire passes, operative time and fluoroscopic images taken were noted.</p><p><b>RESULTS</b>The two computer-assisted systems provided significantly improved accuracy compared to the freehand technique. Each of the parameters, including guidewire passes and number of fluoroscopy images, was significantly lower when using the computer-assisted systems than for freehand-unguided insertion (P <0.05), but operative time was significantly shorter when using freehand-unguided insertion than for the computer-assisted systems (P <0.05). Accuracy, operative time and number of fluoroscopy images taken were similar among the two navigated groups (P >0.05), but guidewire passes in the robot group were significantly less than in the optoelectronic group (P <0.05).</p><p><b>CONCLUSIONS</b>Both bi-planar robot navigation and optoelectronic navigation were similarly accurate and have the potential to improve accuracy and reduce radiation for freehand fluoroscopic targeting for insertion of cannulated screws in femoral neck fractures. Guidewire passes in the robot group were significantly less than in the optoelectronic group. However, both navigated procedures were associated with time-consuming registration and high rates of failed matching procedures.</p>


Subject(s)
Humans , Bone Screws , Femoral Neck Fractures , General Surgery , Hip , Diagnostic Imaging , General Surgery , Radiography , Surgery, Computer-Assisted , Methods
4.
Chinese Journal of Surgery ; (12): 1425-1429, 2010.
Article in Chinese | WPRIM | ID: wpr-270970

ABSTRACT

<p><b>OBJECTIVE</b>To develop a traction reductor for the reduction of lower limb fractures during the minimally invasive surgery and explore its safety and efficacy.</p><p><b>METHODS</b>From February 2007 to March 2009, closed or limited open reduction plus percutaneous plate and screw internal-fixation were conducted in 34 patients with fracture of distal femur and tibia metaphysic, among which there were 3 distal femoral fractures (2 33-B, 1 33-C), 14 proximal tibial fractures (9 41-A, 3 41-B, 2 41-C) and 17 distal tibial fractures (9 43-A, 5 43-B, 3 43-C, 2 Gustilo I a), according to the Association for Osteosynthesis-Orthopaedic Trauma Association (AO-OTA) classification. Besides, closed reduction plus interlocking intramedullary nailing on tibial shaft fracture were applied in 36 patients (7 42-A, 21 42-B, 8 42-C, 2 Gustilo I a). All the 70 patients, with an average age of 37.6 years (range: 17 to 63 years) and average time before surgery of 4.7 d (range: 0.7 to 12.0 d), underwent reduction by self-designed traction reductor for lower limb fracture in the surgery. The reduction duration and C-arm fluoroscopy time were recorded. Recovery of the force line of affected limbs after surgery was determined by whether the line from anterior superior iliac spine to the interdigit between the first and second toe-web passed the patella center. And the distance from bilateral anterior superior iliac spine to medial malleolus tip as well as the difference between lower limbs were recorded to determine the recovery of length after surgery. Meanwhile, the varus-valgus and anteroposterior angulations after reduction were measured by AP and lateral X-ray.</p><p><b>RESULTS</b>The reduction duration was 12.7 min (range: 7 to 31 min); X-ray fluoroscopy time, 1.3 min (range: 0.4 to 3.0 min); length difference between both lower limbs (6.5 ± 1.1) mm; and axial alignment difference (7.0 ± 1.8) mm. The X-ray result showed that varus-valgus angle was (2.75 ± 0.16)°; and anteroposterior angulation (5.13 ± 0.51)°.</p><p><b>CONCLUSION</b>The traction reductor for lower limb fracture could achieve satisfying fracture reduction in the minimally invasive surgery of distal femur, tibia metaphysic and tibial shaft fracture.</p>


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Equipment Design , Fractures, Bone , General Surgery , Leg Injuries , General Surgery , Traction
SELECTION OF CITATIONS
SEARCH DETAIL